Measure scpi commands – AMETEK ReFlex Programming Manual User Manual
Page 103

AC Module Remote Programming
ReFlex Power™ Programming Manual
M380056-03 Rev L
99
4.7
MEASURE SCPI COMMANDS
4.7.1
MEASURE
SCPI
C
OMMAND
S
UMMARY
MEASure<n>
:CURRent?
:VOLTage?
:FREQuency?
:PHASe?
:POWer
[:AC]
[:REAL]?
:APParent?
:VAR?
:PFACtor?
:CFACtor?
:IPEak?
4.7.2
MEASURE
SCPI
C
OMMAND
R
EFERENCE
Command
Description
MEASure<n>
MEASURE subset of SCPI command sets. Valid at Module level only.
:CURRent?
Returns measured RMS output current.
:VOLTage?
Returns the RMS output voltage.
:FREQuency?
Returns the set measured frequency of the unit in Hz
:PHASe?
Returns the setpoint value of the phase angle.
:POWer?
Returns real power measurement
:APParent?
Returns apparent power measurement (VA)
:VAR?
Returns reactive power measurement
:PFACtor?
Returns Power Factor measurement
:CFACtor?
Returns current crest factor
:IPEak?
Returns peak current reading