ReFlex Power™ Programming Manual

DC Module Remote Programming

60

M380056-03 Rev M

3.8

OUTPUT SCPI COMMANDS

3.8.1

OUTPUT

SCPI

C

OMMAND

S

UMMARY

OUTPut[n]

:ISOLation <bool>

:DEFault <bool>

:DEFault?

:ISOLation?

:POLarity <NORM/0/OFF|INV/1/ON>

:POLarity?

:PROTection

:DELAY <NRf>

:DELAY?

:FOLD <NRi>

:FOLD?

:SENSe <bool>

:DEFault <bool>

:DEFault?

:SENse?

:STATe <bool>

:STATe?

:TRIPped?
:MODFault <bool>
:MODFault?

:CLEar <bool>

:CLEar?

:DPDelay

:TIMER <NRf>
:TIMER?

3.8.2

OUTPUT

SCPI

C

OMMAND

R

EFERENCE

Command

Description

OUTPut<n>

Output subsystem. Module ‘n’.

:ISOLation <bool>

Turns 1/ON or 0/OFF, the output isolation relay. The output
voltage must be set to zero prior to issuing this command. The
ISOL relay can’t be opened if Sense relay is closed.

:ISOLation?

Query the state of the ISOLation relay. 0 = open, 1 = closed.

:

DEFault <bool>

Sets DEFault state of ISOL Relay, POR default state is ON. The
ISOL/SENSe relays will be automatically sequenced during the
STATE command.

:

DEFault?

Query DEFault state of Isolation relay

:POLarity
<NORM/0/OFF | INV/1/ON>

Changes the state of the polarity relay. This command requires
that the isolation/sense relays be opened beforehand. If the
isolation relay is closed when this command is attempted, the
state of the polarity relay will not change, and an error message