Power-on conditions – AMETEK ReFlex Programming Manual User Manual
Page 116

ReFlex Power™ Programming Manual
Load Module Remote Programming
112
M380056-03 Rev L
R
EADBACK
F
UNCTIONS
•
Actual measured voltage, power and current
•
Voltage, current and resistance settings
•
Soft voltage, power and current limits
•
Status and Accumulated Status registers
•
Programming error codes
•
Fault codes
•
Manufacturer, power supply model, serial number, and firmware
version identification
5.3
POWER-ON CONDITIONS
Table 5-1 presents the power-on conditions for the Active Loads.
Table 5-1. Load Power-on Conditions
Condition
Default
Current
0 Amps (initial power–on current). Also see
CAL<n>:INIT:CURR
Soft Voltage Limit
Model maximum voltage
Soft Current Limit
Model maximum current
OVP Trip Voltage
Model maximum voltage +7% (initial power–on OVP).
See
CAL<n>:INIT:VOLT:PROT
Input
OFF, relays open
Grouped
No Modules Grouped (example paralleled)
Soft Power Limit
Model power limit