Load Module Remote Programming

ReFlex Power™ Programming Manual

M380056-03 Rev L

117

Command

Description

:PROTection <NRf>

Set the initial undervoltage protection value

:PROTection?

Return the initial undervoltage protection value

:VOLTage

:PROTect?

Get the initial over voltage protection value

:PROTect <NRf>

Set the initial over voltage protection value

:INPut

Calibrate Input subsystem

:CURRent

Calibrate Input Current subsystem

:COUNTS <NRi>

Enter the input current counts

:CALCulate

Calculate the current calibration

:FIVEPOINT <1-5> <NRf>

Set the input current value for each calibration point

:

RANGE <bool>

Change the current range

:CURRent <1-2> <NRf>

Set the input current calibration points

:CONDuctance

Calibrate Conductance subsystem

:COUNTS <NRi>

Set the conductance counts

:CALCulate

Calculate the conductance calibration

:VOLTage <1-2> <NRf>

Set the input voltage calibration points

:MEASure

Calibrate Measure subsystem

:OFFSET

Calibrate Measure Offset subsystem

:CALCulate

Calculate the voltage calibration

:UNLock <string>

Unlock the calibration data file; enables storage of the calibration
constants. The enable string is <“6867”>.

:STORe

Stores the calibration constants.

:LOCK

Locks the calibration data file; disables calibration data store, thereby
preventing storage of the calibration constants.

5.7

MEASURE SCPI COMMANDS

5.7.1

MEASURE

SCPI

C

OMMANDS

S

UMMARY

MEASure<n>

:CURRent?

:VOLTage?

:

POWer?

5.7.2

MEASURE

C

OMMANDS

R

EFERENCE

Command

DESCRIPTION

MEASure<n>

MEASURE subsystem of commands

:CURRent?

Returns the floating-point value of the DC input current.

:VOLTage?

Returns the floating-point value of the DC input voltage.

:

POWer?

Returns floating point value of DC power