Hardware preparation and installation, 1 environmental and power requirements, Table 2-1 – Artesyn SCP-P4040-4G-ENP2 Installation and Use (August 2014) User Manual
Page 21: Environmental requirements, Chapter 2
Chapter 2
SCP-P4040-4G-ENP2 Installation and Use (6806800P60B)
21
Hardware Preparation and Installation
2.1
Environmental and Power Requirements
You must make sure that following environmental requirements meet when board is operated
in your system configuration.
Environmental Requirements
The following table provides the environmental requirement details for the board.
Thermal Requirements
A standard passive heat sink or heat spreader can be provided by Artesyn; 12 CFM system
airflow volume (at 71
o
C) is needed for the heat sink to keep sufficient cooling to the SCP-
P4040-4G-ENP2. Contact your Artesyn sales representative for current information on the
detailed thermal information of the SCP-P4040-4G-ENP2.
Operating temperatures refer to the temperature of air circulation around the board,
but not the component temperature.
Table 2-1 Environmental Requirements
Environmental Factor
Operating
Non-operating
Temperature
-40
o
C to +71
o
C
-50
o
C to +100
o
C
Humidity
to 100% RH
to 100% RH
Vibration Random
(1hr/axis)
0.04g2/Hz, 15 to 2000Hz
(8GRMS)
Shock
30g/11mS(half sine)
Altitude
-60 to 4000 m ASL
Vibration Sine
(10mins/axis)
5G 15 to 2000Hz