Hardware Preparation and Installation

SCP-P4040-4G-ENP2 Installation and Use (6806800P60B)

22

The following table summarized components that exhibit significant temperature raises and
their maximum allowable operating temperature. These components should be monitored in
order to assess thermal performance during customized thermal solution development.

Power Requirements

Table 2-2 Critical Temperature Spots

Component Identifier

Heat Dissipation Power (W) Maximum Allowable Temperature (

o

C)

CPU: P4040

16.8

CPU: 105 (Tj)

GbE Transceiver:
BCM5482

0.86

125 (Tj)

Memory SDRAM: 4GB

3

95 (Tc)

System Overheating
Colling Vents
Improper cooling can lead to system damage and an void the manufacturer's
warranty. To ensure proper cooling and undisturbed airflow through the system do
not obstruct the ventilation openings of the system. Make sure that the fresh air
supply is not mixed with hot exhaust from other devices.

Personal Injury
During operation, hot surfaces may be present on the heat sinks and the components
of the product.
To prevent injury from hot surface, do not touch any of the exposed components or
heatsinks on the product when handling. Use the handle and face plate, where
applicable, or the board edge when removing the product from the enclosure.