Maintenance work

Explanation

Operating

to be done

hours

Pneumatic system
- Check the water level in the

pressure regulator 3

- Clean the filter insert 4

R

- Make leak test of the system

The water level must not rise up to the filter
insert 4.
- Let the water run out of the water separator

under pressure after pressing the drain
plug 5.

The filter insert 4 separates dirt and
condensed water.
- Separate the sewing unit from the

compressed air net.

- Push in drain plug 5.

The pneumatic system of the
sewing unit has to be pressureless.

- Screw the water separator 6 off
- Remove filter insert 4.

Wash the dirty filter tray and the filter insert
with benzine (no solvent!)
and blow them clean.

- Reassemble the water separator

and connect the maintenance unit.