1 command format, 2 local command responses – Comtech EF Data SNM-1000 User Manual

Page 114

Advertising
background image

SNM-1000 Node Control Modem

Revision 3

Operation

MN/SNM1000.IOM

3–72

3.7.24 Change

Return

Channel for Multipoint Data Circuit (MR)

Changes return channel for a multipoint data call.

3.7.24.1 Command

Format

<channel_no> MR <option><phone_number>'cr'


<channel_no>

Prefix channel number.

Valid range: 1 through 30.

1 through 30 are for traffic modems attached to an SNM-1000, operating in
external traffic mode.

MR

Change Return Channel

<option> Option Description

0 Turn return channel off.
1 Return channel request, phone number follows.

<phone_number>

Destination data channel address (phone number).

Max. length: 32 characters.

Valid characters: '1', '2', '3', '4', '5', '6', '7', '8', '9', '0', '*', '#', 'A', 'B', 'C', 'D', '-',
'(' or ')'

Note: The '-' and '('or')' characters are not part of the number and are used to
increase readability. They are stripped out and not passed to the NMS.

3.7.24.2

Local Command Responses

<none>

Command received OK, will be sent to the NMS.

Error <code>: <description> <cr><lf>

Code Description
9 Channel <channel_no> Invalid.
20 Not enough parameters.
21 Bad circuit number.
44 Bad fields or number of parameters, invalid option.

Advertising