1 command format, 2 local command responses – Comtech EF Data SNM-1000 User Manual
Page 115
Advertising

SNM-1000 Node Control Modem
Revision 3
Operation
MN/SNM1000.IOM
3–73
3.7.25
Send Message to Multipoint Data Circuit Originator (MO)
Sends a message to the originator of a multipoint data circuit.
3.7.25.1 Command
Format
<channel_no> MO <message>'cr'
<channel_no>
Prefix channel number.
Valid range: 1 through 30.
1 through 30 are for traffic modems attached to an SNM-1000, operating in
external traffic mode.
MO
Send message to originator
<message> Message
Max. length: 28 characters..
3.7.25.2
Local Command Responses
<none>
Command received OK, will be sent to the NMS.
Error <code>: <description> <cr><lf>
Code Description
9 Channel <channel_no> Invalid.
20 Not enough parameters.