34 DR

®

10 HP CHIPPER

Tools Needed:

5/16" Wrench

3/16" Allen wrench

1/2" socket and ratchet

1. To prevent accidental Starter engagement, disconnect the battery at the negative terminal (Electric

Start model only).

2. Using a 5/16" Wrench, remove both Access Covers (Chipper and Drive Side) from the Chipper Box

(Figure 16).

3. Rotate the Chipper Disk using a stick until the three (3) countersunk Allen Screws and Lock Nuts

attaching the Knife to the Flywheel are visible through the Access Openings (Figure 16).

4. Clean out the heads of the Allen Screws with an awl or sharp tool.

5. Insert a 3/16” Allen wrench into the head of a screw.

6. While holding the Allen wrench, remove the Lock Nut using a 1/2" socket.

7. Repeat Steps 5 and 6 for the remaining two (2) Allen screws.

8. Remove the dull or damaged Knife and visually inspect the Chipper Disk Slot and Knife mounting area

and be sure they are clean and that the replacement Knife will be able to mount flush against the
Chipper Disk.

9. Install a new or sharpened Knife and finger tighten the Allen screws and Lock Nuts (new hardware is

supplied with a new Knife) to hold the Knife to the Chipper Disk.

10. Using a 3/16" Allen wrench and a 1/2" socket, tighten the center Screw and Nut, then tighten the outer

Screw and Nut, and finally tighten the inner Screw and Nut.

11. Double-check all three (3) Screws and Nuts for tightness one more time.

12. Reinstall the Access Covers.

13. Check the gap between the Knife and Wear Plate. See “Adjusting the Knife to Wear Plate Gap” on

page 35.

Figure 16

Access Cover removed,
Chipper side.

Allen Screw
3 places

Knife