Length Control

Fixed Length Decoding—

When fixed length decoding is enabled, the scanner will decode a

bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding—

When variable length decoding is enabled, the scanner will

decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2
values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the

Code 128 Length 1, Length 2 Pro-

gramming Instructions

below.

5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by fol-

lowing the

Code 128 Length 1, Length 2 Programming Instructions

below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first variable length by following the

Code 128 Length 1, Length 2 Pro-

gramming Instructions

below.

5. Set Length 2 to the second variable length by following the

Code 128 Length 1, Length 2

Programming Instructions

below.

START / END