2D Symbologies

152

Magellan

TM

3200VSi

Composite Labels

Disable/Enable GS1 DataBar Omnidirectional 2D Component

When enabled, if a GS1 DataBar Omnidirectional label is decoded which has the 2D linkage
flag set, the 2D component must also be decoded or the base label will be discarded.

When disabled, only the GS1 DataBar Omnidirectional base label will be decoded and trans-
mitted regardless of the state of the linkage flag.

Disable/Enable GS1 DataBar Expanded 2D Component

When enabled, if a GS1 DataBar Expanded label is decoded which has the 2D linkage flag set,
the 2D component must also be decoded or the base label will be discarded.

When disabled, only the GS1 DataBar Expanded base label will be decoded and transmitted
regardless of the state of the linkage flag.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Omnidirectional 2D Component

DEFAULT

Enable GS1 DataBar Omnidirectional 2D Component

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Expanded 2D Component

DEFAULT

Enable GS1 DataBar Expanded 2D Component

Advertising