Figure 3-7: Suction pressure reference numbers

Pump Size

1750

3500

1K 1.5x1-6

7

10

1K 3x1.5-6

10

15

1K 3x2-6 and US-6

10

12

1K 2 x1.5V-6

PT

18

1K 1.5x1-8

1K 1.5x1.5US-8

7

6

1K 2x1.5V-8

PT

16

1K 3x1.5-8

4

4

1K 3x2V-7

PT

11

2K 3x2-8 and US-8

10

7

2K 4x3-8 and US-8

10

13

2K 2x1-10A

8

3

2K 2x1.5V-10A

2K 2x1.5US-10A

8

3

2K 3x1.5-10A

10

17

2K 3x2-10A

10

14

2K 3x2V-10

In-Line

11

9

2K 4x3-10

6

2

2K 4x3-10H

3

na

2K 6x4-10

5

8

2K 6x4-10H

10

na

2K 3x1.5-13

9

5

2K 3x2-13

5

1

2K 4x3-13/13

1

na

2K 4x3-13/12

1

na

2K 4x3-13/11 max

1

2

2K 4x3-13HH

10

na

2K 6x4-13A

1

na

2K 6x4-13A/10.25

1

?

3K 8x6-14A

2

na

3K 10x8-14

PT

na

3K 6x4-16

PT

na

3K 8x6-16A

PT

na

3K 10x8-16 & 16H

PT

na

3K 10x8-17

3

na

12X10-18HD

PT

na

Recessed Impellers

PT

PT

Lo-Flo Pumps

PT

PT

Open Impellers

PT

PT

Notes:
1.

Self-Primer and In-Line pumps not specifically listed above
are to use the standard pump ratings given.
For example: 2K 3x2V-13 and 2K 3x2US-13 pumps utilize the
standard 2K 3x2-13 ratings.

2.

P-T: Only limited by Pressure-Temperature ratings.

3.

Open impeller pumps including the Lo-Flo and Recessed
Impeller products are limited in suction pressure only by the
Pressure-Temperature Ratings.

4.

Sealmatic Pump suction pressure is limited by the repeller

3.4.4

Minimum continuous flow

The minimum continuous flow (MCF) is based on a
percentage of the best efficiency point (BEP). Figure
3-8 identifies the MCF for all Mark 3 pump models
with the exception of the Lo-Flo pump line; there is no
MCF associated with this product line.

Figure 3-8: Minimum continuous flow

Pump size

MCF % of BEP

3500/2900

r/min

1750/1450

r/min

1180/960

r/min

1K3x2-6

20%

10%

10%

1K3x2-7

25%

10%

10%

2K3x2-8

20%

10%

10%

2K4x3-8

20%

10%

10%

2K3x2-10

30%

10%

10%

2K4x3-10

30%

10%

10%

2K6x4-10

40%

10%

10%

2K6x4-10H

n.a.

20%

10%

2K3x1.5-13

30%

10%

10%

2K3x2-13

40%

10%

10%

2K4x3-13

40%

20%

10%

2K4x3-13HH

n.a.

50%

30%

2K6x4-13

60%

40%

10%

3K8x6-14

n.a.

40%

15%

3K10x8-14

n.a.

40%

10%

3K6x4-16

n.a.

50%

10%

3K8x6-16

n.a.

50%

10%

3K10x8-16

n.a.

50%

10%

3K10x8-17

n.a.

50%

10%

3K12x10-18HD

n.a.

60%

10%

All other sizes

10%

10%

10%

3.4.5

Minimum suction pipe submergence

To avoid priming problems, consideration should be
given to minimum suction pipe submergence when
installing Unitized self-priming pumps.