Flowserve Mark 3 Sealed Metallic Durco User Manual

Page 31

Advertising
background image

MARK 3 USER INSTRUCTIONS ENGLISH 71569102 01-13

Page 31 of 72

flowserve.com

Figure 4-22

4.6.4.2c Pump stand limitations
In cases where the pump is rigidly mounted by the
pump stand, both the casing limitations and the pump
stand limitations must be satisfied. Due to the limited
load capacity of the pump stands, it may be
necessary to restrain the piping to prevent loads.
a)

Ensure all applied loads are within the allowable
limits of the casing.

b)

Translate the flange loads using the formulae
found in figure 4-24. Dimensional variables S

RS

,

S

RD

and R

S

can be found in figure 4-23.

c)

Calculate F

T

and F

N

using the formulae found in

figure 4-24.

d)

F

T

and F

N

must be less than F

TMAX

and F

NMAX

found in figure 4-25.

e)

F

T

and F

N

must meet the combination formulae

found in figure 4-25.

Figure 4-23: Dimensional data and casing limitations

Dimensions

m (ft)

Allowable casing loads (suction or discharge)

Forces N (lbf)

Moments Nm (lbf•ft)

SD

SRd

SRs

Rs

Fx

Fy

Fz

Mx

My

Mz

2x1.5V-6

0.381

(1.25)

0.191

(0.625)

0.191

(0.625)

0.163

(0.53)

1 824

(410)

17 685

(3 976)

1 824

(410)

692

(510)

976

(720)

692

(510)

2x1.5V-8

0.432

(1.42)

0.229

(0.75)

0.203

(0.67)

0.163

(0.53)

1 601

(360)

17 685

(3 976)

1 601

(360)

692

(510)

976

(720)

692

(510)

3x2V-7

0.432

(1.42)

0.203

(0.67)

0.229

(0.75)

0.163

(0.53)

2 824

(635)

28 147

(6 328)

2 824

(635)

1 120

(900)

1 722

(1 270)

1 120

(900)

3x1.5V-8

0.483

(1.58)

0.226

(0.74)

0.254

(0.83)

0.163

(0.53)

1 601

(360)

17 685

(3 976)

1 601

(360)

692

(510)

976

(720)

692

(510)

2x1.5V-10A

0.483

(1.58)

0.229

(0.75)

0.254

(0.83)

0.197

(0.65)

1 423

(320)

17 685

(3 976)

1 423

(320)

692

(510)

976

(720)

692

(510)

3x2V-10

0.508

(1.67)

0.241

(0.79)

0.267

(0.88)

0.197

(0.65)

2 402

(540)

28 147

(6 328)

2 402

(540)

1 120

(900)

1 722

(1 270)

1 120

(900)

4x3V-10

0.635

(2.08)

0.292

(0.96)

0.343

(1.13)

0.197

(0.65)

2 823

(638)

28 147

(6 328)

2 823

(638)

1 803

(1 330)

2 549

(1 880)

1 803

(1 330)

3x1.5V-13

0.61

(2.00)

0.292

(0.96)

0.318

(1.04)

0.248

(0.81)

1 134

(255)

17 685

(3 976)

1 134

(255)

692

(510)

976

(720)

692

(510)

3x2V-13

0.61

(2.00)

0.292

(0.96)

0.318

(1.04)

0.248

(0.81)

2 002

(450)

28 147

(6 328)

2 002

(450)

1 120

(900)

1 722

(1 270)

1 120

(900)

4x3V-13

0.711

(2.33)

0.33

(1.08)

0.381

(1.25)

0.248

(0.81)

2 535

(570)

28 147

(6 328)

2 535

(570)

1 803

(1 330)

2 549

(1 880)

1 803

(1 330)

6x4V-13

0.762

(2.50)

0.356

(1.17)

0.406

(1.33)

0.248

(0.81)

2 891

(650)

83 195

(18 704)

2 891

(650)

2 210

(1 630)

3 119

(2 300)

2 210

(1 630)


Figure 4-24: Pump stand load translation formulae

Forces

Moments

F

XC

= F

XS

+ F

XD

M

XC

= M

XS

+ M

XD

+ (F

ZS

× SR

S

) - (F

ZD

× SR

D

)

F

YC

= F

YS

+ F

YD

M

YC

= M

YS

+ M

YD

F

ZC

= F

ZS

+ F

ZD

M

ZC

= M

ZS

+ M

ZD

- (F

XS

× SR

S

) + (F

XD

× SR

D

)

TMax

s

zc

yc

s

zc

xc

T

F

R

M

F

R

M

F

F





×

+

+





×

+

=

2

2

707

.

0

707

.

0

MAX

N

s

yc

xc

zc

N

F

R

M

M

F

F

_

707

.

0

+

+

=

Advertising