Flowserve Mark 3 Sealed Metallic Durco User Manual

Page 26

Advertising
background image

MARK 3 USER INSTRUCTIONS ENGLISH 71569102 01-13

Page 26 of 72

flowserve.com


Figure 4-15: Baseplate correction factors

Figure 4-16: Coordinate system

Base Type

Grouted

Bolted

Stilt Mounted

Type A

1.0

0.7

0.65

Type B - Polybase

1.0

n/a

0.95

Type C

n/a

1.0

1.0

Type D

1.0

0.8

0.75

Type E - PIP

1.0

0.95

n/a

Type T5000

1.0

n/a

n/a

Polyshield -

baseplate/foundation

1.0

n/a

n/a

Figure 4-14: Casing Material Correction Factors

Temp

˚C

Temp

˚F

Material Group No.

1.0

1.1

2.1

2.2

2.4

2.8

3.2

3.4

3.5

3.7

3.8

3.17

Ti

Cr

DCI

Carbon

Steel

Austenitic Steels

Nickel and Nickel Alloys

Ti,
Ti-

Pd,

Zr

High

Chrome

-18 to

171˚C

(0 to

340˚F)

Type

304
and

304L

Type

316
and

316L

Type

321

CD-

4MCu Nickel Monel Inconel

Hast

B.

Hast

C.

Alloy

20

-129

-200

1.00

1.00

1.00

0.50

0.83

-73

-100

1.00

1.00

1.00

1.00

0.50

0.83

0.93

1.00

1.00

0.83

0.89

-29

-20

0.89

1.00

1.00

1.00

1.00

1.00

0.50

0.83

0.93

1.00

1.00

0.83

0.89

0.65

38

100

0.89

1.00

1.00

1.00

1.00

1.00

0.50

0.83

0.93

1.00

1.00

0.83

0.89

0.65

93

200

0.83

0.94

0.83

0.86

0.93

1.00

0.50

0.74

0.88

1.00

1.00

0.72

0.86

0.65

150

300

0.78

0.91

0.75

0.78

0.83

0.92

0.50

0.69

0.82

1.00

1.00

0.65

0.81

0.65

205

400

0.73

0.88

0.69

0.72

0.69

0.85

0.50

0.67

0.77

0.98

0.98

0.58

0.69

0.65

260

500

0.69

0.83

0.63

0.67

0.64

0.80

0.50

0.66

0.74

0.92

0.92

0.54

0.57

315

600

0.65

0.76

0.60

0.63

0.60

0.77

0.50

0.66

0.74

0.84

0.84

0.50

0.45

344

650

0.63

0.74

0.60

0.62

0.60

0.66

0.73

0.82

0.82

0.39

370

700

0.74

0.59

0.60

0.58

0.66

0.73

0.79

0.79

0.33

Advertising