5.2 Pump lubricants

5.2.1 Recommended oil lubricants

Oil

Splash lubrication

Force feed lubrication

Viscosity

mm ²/s 40 ºC

32

68

46

Temp. maximum

ºC (ºF)

65 (149)

80 (176)

-

Centifugal pump

lubrication

Designation

according to

DIN51502 ISO VG

HL/HLP 32

HL/HLP 68

HL/HLP 46

BP

BP Energol HL32

BP Energol HLP32

BP Energol HL68

BP Energol HLP68

BP Energol HL46

BP Energol HLP46

DEA

Anstron HL32

Anstron HLP32

Anstron HL68

Anstron HLP68

Anstron HL46

Anstron HLP46

Elf

OLNA 32

HYDRELEF 32

TURBELF 32

ELFOLNA DS32

TURBELF SA68

ELFOLNA DS68

TURBELF SA46

ELFOLNA DS46

Esso

TERESSO 32

NUTO H32

TERESSO 68

NUTO H68

TERESSO 46

NUTO H46

Mobil

Mobil DTE oil light

Mobil DTE13

MobilDTE24

Mobil DTE oil heavy medium

Mobil DTE26

Mobil DTE oil medium

Mobil DTE15M

Mobil DTE25

Q8

Q8 Verdi 32

Q8 Haydn 32

Q8 Verdi 68

Q8 Haydn 68

Q8 Verdi 46

Q8 Haydn 46

Shell

Shell Te llus 32
Shell Tellus 37

Shell Tellus 01 C 68

Shell Tellus 01 68

Shell Tellus 01 C 46

Shell Tellus 01 46

Texaco

Rando Oil HD 32

Rando Oil HD-AZ-32

Rando Oil 68

Rando Oil HD C-68

Rando Oil 46

Rando Oil HD B-46

Oil companies and lubricants

Wintershall

(BASF Group)

Wiolan HN32

Wiolan HS32

Wiolan HN68

Wiolan HS68

Wiolan HN46
Wiolan HS46


5.2.2 Recommended grease lubricants

Grease nipples

Grease

NLGI 2 *

NLGI 3 **

Temp. range ºC

(ºF)

-20 to +100
(-4 to +212)

-20 to +100
(-4 to +212)

Designation

according to DIN

K2K-20

K2K 30

BP

Energrease LS2

Energrease LS3

DEA

Glissando 20

Glissando 30

Elf

Elfmulti 2

Elfmulti 3

Esso

Beacon 2

Beacon 3

Mobil

Mobilux 2

Mobilux 3

Q8

Rembrandt 2

Rembrandt 3

Shell

Alvania Fett G2
Alvania Fett R2

Alvania R3

Texaco

Multilak 20

Multilak EP2

Multilak 30

Multilak EP3

Wintershall

(BASF Group)

Wiolub LFK 2

-

SKF

LGMT 2

LGMT 3

Silkolene

G55/T

G56/T

* NLGI 2 is an alternative grease and is not to be mixed with other

grades

** Factory packed bearings for the temperature range with grease

nipples


5.2.3 Recommended fill quantities
Refer to section 3.4.2, Pump and impeller data.

5.2.4

Lubrication schedule


5.2.4.1 Oil lubricated bearings
Normal oil change intervals are 4 000 operating hours
or at least every 6 months. For pumps on hot service
or in severely damp or corrosive atmosphere, the oil will
require changing more frequently. Lubricant and
bearing temperature analysis can be useful in
optimizing lubricant change intervals.

The lubricating oil should be a high quality mineral oil
having foam inhibitors. Synthetic oils may also be used
if checks show that the rubber oil seals will not be
adversely affected.

The bearing temperature may be allowed to rise to
50 ºC (122 ºF).above ambient, but should not exceed
82 ºC (180 ºF). A continuously rising temperature, or
an abrupt rise, indicate a fault.