Page 8 of 54

®

occur if there is heat input to the liquid. This can occur
if the pump is stationary or running.

Bursting of liquid containing parts due to freezing must
be avoided by draining or protecting the pump and
ancillary systems.

Where there is the potential hazard of a loss of a seal
barrier fluid or external flush, the fluid must be
monitored.

If leakage of liquid to atmosphere can result in a
hazard, the installation of a liquid detection device is
recommended.

1.6.4.7 Maintenance to avoid the hazard

CORRECT MAINTENANCE IS REQUIRED TO

AVOID POTENTIAL HAZARDS WHICH GIVE A RISK
OF EXPLOSION
The responsibility for compliance with maintenance
instructions is with the plant operator.

To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting materials
used must not give rise to sparking or adversely affect
the ambient conditions. Where there is a risk from
such tools or materials, maintenance must be
conducted in a safe area.

It is recommended that a maintenance plan and
schedule is adopted. (See section 6, Maintenance.)

1.7 Nameplate and warning labels

1.7.1 Nameplate
For details of nameplate, see the Declaration of Conformity.

1.7.2 Warning labels






MECHANICAL SEAL WARNING

ROTATION WARNING

P/N 2113931-001

P/N 2113932-001











GROUT WARNING

LIFTING WARNING

P/N 2113934-001

P/N 9901701-001

WARNING

MECHANICAL SEAL FITTED

DO NOT ADJUST PUMP CLEARANCE

WITHOUT REFERENCE TO

MANUFACTURER’S INSTRUCTION MANUAL

WARNING

BEFORE STARTING THE PUMP ON SERVICE,

CHECK TO ENSURE CORRECT ROTATION OF

MOTOR. FAILURE TO DO THIS COULD RESULT

IN SERIOUS DAMAGE TO THE EQUIPMENT.

WARNING

BEFORE GROUTING, REALIGN THIS UNIT.

RECHECK ALIGNMENT BEFORE STARTING,

FAILURE TO DO THIS COULD RESULT IN
SERIOUS DAMAGE TO THE EQUIPMENT.

REFER TO INSTALLATION MANUAL AND, OR

COUPLING INSTRUCTIONS FOR METHOD OF

CHECKING ALIGNMENT.

WARNING

THESE EYEBOLTS

ARE TO BE USED FOR LIFTING BEARING

CARTRIDGE AND SHAFT ONLY.

DO NOT USE FOR LIFTING ENTIRE UNIT

Advertising