7 faults; causes and remedies – Flowserve FRBH User Manual

Page 42

Advertising
background image

FRBH, FRBHX AND FRBHS USER INSTRUCTIONS ENGLISH 71569178 10-04


Page 42 of 54

®




7 FAULTS; CAUSES AND REMEDIES

FAULT SYMPTOM

P u m p o v e r h e a t s a n d s e i z e s

B e a r i n g s h a v e s h o r t l i f e

P u m p v i b r a t e s o r i s n o i s y

M e c h a n i c a l s e a l h a s s h o r t l i f e

M e c h a n i c a l s e a l l e a k s e x c e s s i v e l y

P u m p r e q u i r e s e x c e s s i v e p o w e r

P u m p l o s e s p r i m e a f t e r s t a r t i n g

I n s u f f i c i e n t p r e s s u r e d e v e l o p e d

I n s u f f i c i e n t c a p a c i t y d e l i v e r e d

P u m p d o e s n o t d e l i v e r l i q u i d

PROBABLE CAUSES

POSSIBLE REMEDIES

A. System troubles

l

l Pump not primed.

l

l l l Pump or suction pipe not completely filled with

liquid.

Check complete filling. Vent and/or prime.

l

l l l Suction lift too high or level too low.

l l

l l Insufficient margin between suction pressure and

vapour pressure.

Check NPSHa>NPSHr, proper submergence,
losses at strainers/fittings.

l l l Excessive amount of air or gas in liquid.

Check and purge pipes and system.

l l l Air or vapour pocket in suction line.

Check suction line design for vapour pockets.

l l Air leaks into suction line.

Check suction pipe is airtight.

l l Air leaks into pump through mechanical seal,

sleeve joints, casing joint or pipe plugs.

Check and replace faulty parts.
CONSULT FLOWSERVE.

l

l Foot valve too small.

Investigate replacing the foot valve.

l

l Foot valve partially clogged.

Clean foot valve.

l

l l l Inlet of suction pipe insufficiently submerged.

Check out system design.

l l l Speed too low.

CONSULT FLOWSERVE.

l Speed too high.

CONSULT FLOWSERVE.

l l l Total head of system higher than differential head

of pump.

l Total head of system lower than pump design

head.

Check system losses.
Remedy or CONSULT FLOWSERVE.

l Specific gravity of liquid different from design.

l l l Viscosity of liquid differs from that for which

designed.

Check and CONSULT FLOWSERVE.

l l

Operation at very low capacity.

Measure value and check minimum permitted.
Remedy or CONSULT FLOWSERVE.

l l

l Operation at high capacity.

Measure value and check maximum permitted.
Remedy or CONSULT FLOWSERVE.

Advertising
This manual is related to the following products: