3 geared limit switch, 1 setting limit switch – Flowserve UEX Limitorque User Manual

Page 10

Advertising
background image

Limitorque UEX FCD LMENIM1205-03-AQ – 05/15

10

5. Loosen balancing screws and install the torque switch. The base of the torque switch should be

flush against the compartment and the hole for the mounting screw should be aligned.

6. Install the mounting screw.

7. Tighten the balancing screws.

a

CAUTION: The balancing screws should not be touched except during the balancing procedure.

The switch is now balanced and ready for the pointers to be returned to their original settings.

3.3 Geared Limit Switch

a

CAUTION: The geared limit switch is not preset at the factory and must be adjusted after the
actuator has been mounted on associated equipment.

• Disconnect all incoming power to the actuator prior to opening the limit switch compartment and

adjusting the switch.

• Consult the relevant wiring diagram for limit switch contact development. All L120 units are

supplied with 16-contact limit switches - four switches on each of the four rotors. Two rotors are
used for end of travel indication. The remaining two rotors may be adjusted for any intermediate
point of travel.

• Do not use abrasive cloth to clean the contacts on the limit switch.
• Do not attempt to repair gearing in the limit switch. Replace entire gear frame assembly if

necessary.

3.3.1 Setting Limit Switch

Set the limit switch as follows. All item letters and piece numbers refer to Figure 3.2.

NOTE: See chart below for maximum number of drive sleeve turns for each unit size. The Intermediate
Shaft (B), shown in Figure 3.2, may take a considerable number of turns before rotor trip occurs.

Table 3.1 – Maximum Number of Drive Sleeve Turns for Standard Four-Gear and Optional Five-Gear

Limit Switches

Actuator Size

Four-Gear

Five-Gear

L120-10

630

6300

L120-20

740

7400

L120-40

640

6400

c

WARNING: Potential Explosion Hazard. Do not use a variable speed electric drill for setting the limit
switch in an explosive environment.

a

CAUTION: When setting the limit switch rotor segments (cams) using a variable speed electric drill,
do not run drill at speeds higher than 200 RPM. Operating the drill at high speeds can damage the
gearing within the limit switch.

Advertising