3 product description – Flowserve UEX Limitorque User Manual
Page 5
5
Limitorque UEX FCD LMENIM1205-03-AQ – 05/15
flowserve.com
1.3 Product Description
The UEX is designed for use with the three-phase L120 electric actuators for weatherproof, explosion-
proof, and submersible applications. The UEX is field-retrofittable to replace existing UEC-3 controllers.
With state-of-the-art controls based on MX control technology, the UEX offers an expanded feature set
compared to the UEC-3.
Please refer to LMENIM2306 for detailed menu configurations
Table 1.1 Standard Application Voltages with +/- 10% Nominal Range
Design Voltage
Application Voltage
230 VAC, 60 Hz, 3 ph
208/220/230/240 VAC, 60 Hz, 3 ph
460 VAC, 60 Hz, 3 ph
380/400/415/440 VAC, 50 Hz, 3 ph
380/440/460/480 VAC, 60 Hz, 3 ph
525 VAC, 50 Hz, 3 ph
525 VAC, 50 Hz
575 VAC, 60 Hz, 3 ph
550/575/600 VAC, 60 Hz, 3 ph
Figure 1.1 – UEX Local Control Panel
VIEW A-A
Blue
Knob
Red
Knob
Open
(Yes)
Close
(No)
Lights (2)
CSE Control
Station
Selector Switch Detail
(Knob removed for clarity)
A
A