6

Command List:

CON

Connect input to output(s)

HAU

HDMI Audio Output command

HEDID

HDMI EDID setting

INSRC

Input Source command

SAO

Stereo Audio Output command

PRESET

Preset Recall command

RST

Reset

DV-MFSW-94

BAUD

Sets the RS232 baud rate

IPADR

Sets the IP address

STAT

Universal Status command


NOTE:

All commands are terminated with a carriage return (0Dhex) represented by <cr>

The default baud rate is 38400 bps.

6.1 Set CON Command

Tells the DV-MFSW-94 which outputs to connect to which input
CON

id input “(“ output “,” output “,” ……”)”[“;” input”(“output,,,,”)”] <cr>

WHERE:

CON

3 ASCII byte command name

id

2 byte unit ID

input

An input number between 0 – 9, zero representing no input.

“(“

Parentheses indicating the start of the outputs to connect the input to.

output

an output number 1 – 4 to connect to the input. Multiple outputs can be included in the list
separated by a comma.

“)”

Parentheses to end the list of outputs

“;” Delimiter separating additional definitions
<cr>

Carriage Return (0Dhex)

Example:

Connect Unit 01 input 1 to outputs 2, 3 and 4 and input 2 to output 1.
CON 01 1(2,3,4); 2(1)

<cr>