 A maximum of 16 Model LE200-RMs can be connected within a single zone or Page/Party

®

subsystem.

 Avoid having more than one Model LE200-RM connected to a particular Page/Party

®

cable. Instead,

use the LVDS link whenever possible.

 Line extenders can NOT be wired in a loop architecture for redundant connections as shown below:

Figure 12. Invalid Loop Connection of Page/Party

®

Systems

 All contact input states are ORed together to determine a contact output state.
 All remote page line audio detected states are ORed together to determine the state of the page line

audio detected relay contact output.

 All remote page line ground fault states are ORed together to determine the state of the page line

ground fault relay contact output.

 When enabled, 50 kHz VLC signal on any page line is transmitted to all page lines.
 SmartSeries FSK data on any page line is transmitted to all page lines.
 Manual retraining of echo cancellation at one Model LE200-RM also requests it at all digitally

interconnected Model LE200-RMs.