Table 33 below outlines the functions settings for DIP switch S2:

Table 33. Function Settings for DIP Switch S2

Function Setting

T1/E1 Selection

S2-1: OFF; T1 mode selected (default setting)

S2-1: ON; E1 mode selected

Receive

Equalizer Gain

Limit

E1
S2-2: ON; −12 dB Short Haul
S2-2: OFF; −43 dB Long Haul

T1
S2-2: ON; −36 dB Long Haul
S2-2: OFF; −30 dB Limited Long Haul (default setting)

Line Encoding

S2-3: ON; B8ZS or T1 or HDB3 for E1
S2-3: OFF; AMI (default setting)

Transmit LIU

Wave Shape

(Build-out)

E1

S2-4 S2-5 S2-6

ON

ON

ON

75 ohms

OFF

ON

ON

125 ohms

ON

ON

OFF

75 S ohms with High Return Loss

OFF

ON

OFF

125 S ohms with High Return Loss

T1

S2-4 S2-5 S2-6

ON

ON

ON

DSX-1 (0 to 133 feet) 0 dB CSU (default setting)

OFF

ON

ON

DSX-1 (133 to 266 feet)

ON

OFF

ON

DSX-1 (266 to 399 feet)

OFF

OFF

ON

DSX-1 (399 to 533 feet)

ON

ON

OFF

DSX-1 (533 to 655 feet)

OFF

ON

OFF

−7.5 dB CSU

ON

OFF

OFF

−15 dB CSU

OFF

OFF

OFF

−22.5 dB CSU

Receive LIU

Termination

S2-7: ON; S2-8: ON; Receive side termination disabled
S2-7: OFF; S2-8: ON; Receive side 120 ohms enabled
S2-7: ON; S2-8: OFF; Receive side 100 ohms enabled (default setting)
S2-7: OFF; S2-8: OFF; Receive side 75 ohms enabled

Transmit Data

Source

S2-9: ON; S2-10: ON; Standard data (default setting)
S2-9: OFF; S2-10: ON; Transmit pseudo-random bit sequence (PRBS)
S2-9: ON; S2-10: OFF; Transmit alternating ones and zeros
S2-9: OFF; S2-10: OFF; Transmit unframed all ones