Contact closure output connections – GAI-Tronics LE200-RM Rack-Mount Page/Party Line Extender User Manual

Page 33

Advertising
background image

Pub. 42004-392G

M

ODEL

LE200-RM

R

ACK

-M

OUNT

P

AGE

/P

ARTY

®

L

INE

E

XTENDER

P

AGE

31 of 56

e:\standard ioms - current release\42004 instr. manuals\42004-392g.doc
09/14

Table 29. TB8 and TB9

Terminal Designator

Description

TB8

Input 1 (+)

Input contact 1

TB8

Input 1 (−)

TB8

Input 2 (+)

Input contact 2

TB8

Input 2 (−)

TB8

Input 3 (+)

Input contact 3

TB8

Input 3 (−)

TB9

Input 4 (+)

Input contact 4

TB9

Input 4 (−)

TB9

Input 5 (+)

Input contact 5

TB9

Input 5 (−)

Contact Closure Output Connections

Seven relay outputs are provided. Each relay output provides two contact sets and each contact set
consists of normally open (NO), common (C) and normally closed (NC) contacts. Outputs 1–5 are
activated by inputs 1–5 on the remote Line Extender. Output 6 is activated when page line audio is
detected and output 7 is activated when a page line ground fault is detected. Terminals are provided on the
Model 12118-012 Kit for each relay contact and are labeled with the relay contact description next to the
terminal block TB1-7 as shown below.

Figure 16. Relay Output Terminals

Advertising
This manual is related to the following products: