Function Testing

The Model LE200-RM can manually activate some of the system “control” functions to aid in system
trouble-shooting or commissioning. Functions include relay contact outputs, party line off-hook
generation, page line ground fault generation, and the LVDS connector LEDs. Similar to the audio test
generation, rotary switch SW1 and DIP switch SW2 are used to activate the various functions. Refer to the
tables below for valid switch settings.

Table 50. Generated Data Signaling on Page Line

SW1

Selected Data Signal

SW2-5 SW2-6 SW2-7 SW2-8

B

50.087 kHz sine wave (VLC tone)

Closed Open Open

Closed

30.720 kHz sine wave (SmartSeries data 0)

Open

Closed

Open

Closed

32.941 kHz sine wave (SmartSeries data

1)

Closed Closed Open Closed

SmartSeries data 1/0 pattern

Open Open Closed Closed

Random waveform containing all signals above. Closed Open Closed Closed

N

OTE

: Remember to restore SW1 to “0” and SW2 to its initial setting when no longer generating test

signals.

Table 51. Activate Contact Closure Outputs

SW1 Selected

Function

SW2

SW2-8

7

Activate contact output #1

SW2-1 Closed

Closed

Activate contact output #2

SW2-2 Closed

Closed

Activate contact output #3

SW2-3 Closed

Closed

Activate contact output #4

SW2-4 Closed

Closed

Activate contact output #5

SW2-5 Closed

Closed

Activate page audio detect contact

SW2-6 Closed

Closed

Activate page ground fault detect contact

SW2-7 Closed

Closed

N

OTE

: Remember to restore SW1 to “0” and SW2 to its initial setting when no longer generating test

signals.

Table 52. Generate Off-Hook & Ground Fault Conditions

SW1 Selected

Function

SW2

SW2-8

7

Party line #1 off-hook

SW2-1 Closed

Closed

Party line #2 off-hook

SW2-2 Closed

Closed

Party line #3 off-hook

SW2-3 Closed

Closed

Party line #4 off-hook

SW2-4 Closed

Closed

Party line #5 off-hook

SW2-5 Closed

Closed

Page line ground fault

SW2-6 Closed

Closed

N

OTE

: Remember to restore SW1 to “0” and SW2 to its initial setting when no longer generating test

signals.