Contact closure input connections – GAI-Tronics LE200-RM Rack-Mount Page/Party Line Extender User Manual

Page 32

Advertising
background image

Pub. 42004-392G

M

ODEL

LE200-RM

R

ACK

-M

OUNT

P

AGE

/P

ARTY

®

L

INE

E

XTENDER

P

AGE

30 of 56

e:\standard ioms - current release\42004 instr. manuals\42004-392g.doc
09/14

Table 28. Terminal Block P19

Terminal Designator Description

P19-1 TX

Ring

Data TRANSMIT wire pair

P19-2 TX

Tip

P19-3 RX

Ring

Data RECEIVE wire pair

P19-4 RX

Tip

NOTE

Do NOT connect the TX (transmit) signal to the RX (receive) signal on the same

Model LE200-RM Line Extender. Doing so creates a feedback path that usually results in extremely
loud oscillations on the page line and the party lines. The contact outputs may also activate.

Contact Closure Input Connections

Contact inputs are typically connected to switches or mechanical relay contacts. Five inputs are available
on Model 12118-012 Kit with each input requiring two conductors. Connect the normally open contact
across the top and bottom. If using a solid state switch as the input device, observe polarity of the
connection (−) on bottom, (+) on top. Each input cable connection point is labeled next to the terminal
block TB8 and 9 as shown in Figure 15 below.

Figure 15. Input Contact Terminals

Advertising