Disconnect options, Extended control output operation – GAI-Tronics 295-001W, 295-001F Analog Clean Phone User Manual

Page 27

Advertising
background image

P

UB

.

42004-484E

A

NALOG

C

LEAN

P

HONE

®

T

ELEPHONES

P

AGE

27 of 33

f:\standard ioms - current release\42004 instr. manuals\42004-484e.docx
01/15

Disconnect Options

Several options are available for disconnecting a call. Any combination of disconnect options may be
used. Select the method that best suits the application, and follow the appropriate programming
directions.

Table 8. Disconnect Options


Feature

Key
Sequence


Description


Default

Call Time-out
Disconnect
Option

# 1 2 N N

This feature programs the maximum length of a call if no other
disconnect features are used. The valid entries are 1–99,
representing 1-minute increments and 0 representing 4.5 hours.
The call duration timer begins when the telephone goes off-hook.
The telephone automatically disconnects after the programmed
time-out period elapses.

Example: To make the maximum call length 2 minutes,
enter # 1

2

0

2

.

10 (10
minutes)

Dial Tone
Disconnect
Option

# 1 9 L

N

OTE

: Use this option only if no other disconnect options are

available.
If this option is enabled, the telephone automatically terminates a
call if it detects a dial tone continuously for 10 seconds, such as if
the called party hangs up. To enable the dial tone disconnect, L=1.
To disable the dial tone disconnect, L = 0.

Example: To enable the dial tone disconnect, enter #

1

9

1

.

To disable the dial tone disconnect, enter #

1

9

0

.

0
(Disabled)

N

OTE

: Simply pressing the on/off push button will disconnect the call.

Extended Control Output Operation

Output 1 can be programmed for extended operation (remain closed) for up to 255 minutes (in 1-minute
increments) after the emergency call ends.

Table 9. Extended Strobe Operation


Feature

Key
Sequence


Description


Default

Extended
Strobe
Operation

# 2 5 N N N

Sets the duration of the activation of the Output 1 contact starting
at the end of a call. Use entries 001–255, representing 1 minute to
255 minutes in 1-minute increments.
Use 000 to disable this feature.
To set a duration of 7 minutes, enter

#

2

5

0

0

7

.

0 0 0
(Disabled)

Advertising