Output 4 Control Setup

The command (DTMF key sequence) that triggers the timed activation of Output 4 contact closure (TB5)
is configurable. The sequence can contain up to eight DTMF digits in the 0–9 range. The first digit must
not be 0 (zero). Some examples of valid control sequences are: 87654321; 832; and even a single digit
such as 7. The duration of the activation (closure) of Output 4 can be set in the range of 0.1 to 12.7
seconds in 0.1-second increments.

Table 10. Output 4 Control Options


Feature

Key
Sequence


Description


Default

Control
Sequence

N N..* 8

Assigns the digits NN.. as the command key sequence that
triggers the timed activation of Output 4. NN is a sequence
of 1–8 digits, with the first digit not zero. To assign “726”
as the control sequence, enter

7

2

6

*

8

.

90125

Duration of
Timed
Activation

# 2 6 N N N

Sets the duration of the activation of the Output 4 contact
when triggered by the control sequence. Use entries 001–
127, representing 0.1 second to 12.7 seconds in
0.1-second increments.
Use 000 to disable this feature.
To set a duration of 7 seconds, enter

#

2

6

0

7

0

.

5 seconds