Installation

1052

2-3

SUPPLY LINE


The supply line for satellite dispensing units is connected to the satellite outlet of the dispenser.

Use new galvanized or fiberglass (see note) pipe, 1 1/2" (38.1mm) minimum diameter.


NOTE:

Fiberglass pipe is to be installed according to manufacturer’s specifications and
requirements.


Be sure both the pipe and the tank are clean. Foreign matter entering the satellite can cause
extensive damage. Obstructions in the supply line can create pump problems and reduced flow
rate.

Make sure all pipe threads are properly cut and the inside reamed to remove burrs. Use Listed
gasoline-resistant compound on all joints of gasoline handling piping. Sealing compound must
also be resistant to Gasohol (Ethanol and Methanol). Do not use Teflon Pipe Sealing Tape. Use
gasoline-resistant pipe compound on male threads only; pipe compound used on female threads
can be squeezed into the supply line where it can enter the product stream and become lodged in
the pump or meter. Install swing joints under the pump and at the satellite to avoid breaks in the
supply line from settling or frost heave.

Upon completion of installation, all liquid-carrying lines must be checked for leaks.