Gasboy 9820A Series User Manual

Page 37

Advertising
background image

Pump Operation

03/07/03

5-5

Pulse Rate

SW2-1 SW2-2 SW2-3

None

None

Closed

Open

Open

Open

Open

Open

500

1000

Closed

Open

Open

Open

Closed

Closed

100

250

Closed

Open

Closed

Closed

Open

Open

10

1

Closed

Open

Closed

Closed

Closed

Closed

Pulse Rate

Display

500:1

1000:1

XXX.XXX

XXX.XXX

100:1

250:1

XXX.XX

XXX.XXX

10:1

1:1

XXX.

XXX.X

Disabled

Enabled

Timeout

Closed

Open

SW2-4

Pulser Output Rate Switches
When the 9820A is connected to external control
equipment other than a GASBOY CFN system
(standalone), the pulser signals are sent out via the 9820A
Pump I/F PCB. The pulse rate required by the monitoring
equipment can be configured by setting the switches as
shown in the chart at right. The pulse rate represents
pulses per gallon (PPG, domestic) or pulses per liter (PPL,
international). For domestic units, the pulse rate can be up
to 1000 PPG. For international units, the pulse rate can be
up to 250 PPL for all other models. This switch may need
to be sealed by a Weights and Measures paper seal if the
9820A is used for the resale of product.


Leading zeros are always suppressed in the hundreds and
tens positions to the left of the decimal point. When in
standalone mode, positions to the right of the decimal point
are displayed based on the pulse rate selected as shown in
the table at right.

Timeout Switch
When the 9820A is in standalone mode, it will turn off an
active hose if it doesn't detect pulses for 4 minutes, 15
seconds. This timeout feature can be disabled by setting
switch SW2-4 to OPEN.