Removing, Figure 1 – Gasboy Atlas Discharge User Manual
Page 6

Installing the M06228K001 or M06228K002 Kit
Page 6
MDE-4503 Atlas Discharge and Valve Conduit Retrofit Kit • July 2005
Removing
1
Remove the covers to the junctions box. See
Save bolts for reuse.
Figure 1: Junction Box
2
Mark the valve wire connections to correspond with the red, yellow and black valves wires, to
aid in reconnecting to the correct wire. (If there are two valves, also mark those wires.)
3
Remove and retain the wire nuts to the indicated wires.
4
Loosen the valve conduit unions at the junction box. Reference
.
To remove the discharge line:
5
Disconnect and remove the bolts to the formed flanges to the discharge fitting on the bottom of
the meter and at the unit discharge fitting. See
Junction Box
Existing Valve
Conduit Unions
Hint:
Place rag here on
each side to prevent
tools from falling in
and getting lost.