15 - key option configuration, Configuring the site controller, System parameters (sys_par) – Gasboy CFN III Config Mnl V3.4 User Manual

Page 103: 15 – key option configuration

Advertising
background image

MDE-4316C CFN Series CFN III Configuration Manual for Windows NT® · April 2007

Page 97

Key Option Configuration

15 – Key Option Configuration

A Key Option is available for Islander II sites. The following configuration adjustments must
be made to the Site Controller configuration for this option.

Configuring the Site Controller

System Parameters (SYS_PAR)

The following setting must be used to configure the Site Controller to accept smart keys.

Page 2: Club card format - field widths

Digits in limitation code = 1
Digits in authorization code = 1
Digits in price level = 1
Digits in restriction code = 1
Digits in expiration date = 4

Page 3: Club card format - offsets

Limitation code offset = 0
Authorization code offset = 1
Price level offset = 2
Restriction code offset = 3

Reader verification - page 4

The Key Option on the CFN allows the PIN number to be stored on the key. If you are using
this option, when the user enters the PIN at the reader, it is verified against the PIN stored on
the key. These PIN numbers do not use the standard CFN algorithm and are verified at the
reader. In order to use this option, you must set the following reader verification parameters:

Require PIN (reader) = none
Check PIN (reader) = none

Note: The check digit on the key must be set to require PIN in order to verify the key PIN

number. Refer to the Gasboy Key Encoder/Maintenance Terminal Operation Manual,
C08380 for more information.

If you are using key and card combinations (verifying the PIN for the card), code keys (using
the Lookup tables), or verifying the PIN based on the account number and not the number
stored on the key, you must set the following reader verification parameters:

Check PIN (reader) = club

Note: The check digit on the key must be set to NOT require PIN. Refer to the Gasboy Key

Encoder/Maintenance Terminal Operation Manual, C08380 for more information. If
you are verifying the PIN based on the account number from the key, set the following
parameter:

Require PIN (reader) = club

Miles-per-gallon package - page 13

Advertising