Appendix 5: sample layouts – Infloor Standard Electric Cable User Manual

Page 20

Advertising
background image

20

Infloor Installation Manual

Appendix 5: Sample Layouts

Sink

C

oun

ter t
op and c

abinetr

y

C

oun

ter t

op and c

abinetr

y

Island

Zone 1a

Zone 1b

Zone 2

Zone 1

Control

Control

Zone 2

Control

Zone 2

Sensor

Zone 1

Sensor

1 spool

70 sq . ft .

2-1/2” spacing

1 spool

240 sq . ft .

3” spacing

Spool

termination

1 spool

120 sq . ft .

2-1/2” spacing

Strap

Range

Counter/cabinetry

Counter and cabinetry

Sink

Pantry

Dish-

washer

Microwave

Floor

Sensor

Spool termination

Spool

termination

Spool

termination

1 spool

120 sq . ft .

3” spacing

1 spool

112 sq . ft .

2” spacing

Strap

Kitchen and Family Room (normal heat loss, slab on grade with insulation)
Two zones, 240 volts: Kitchen/Zone 1a = 1 spool, 70 sq .ft ., 2-1/2” spacing;

Zone 1b = 1 spool; 120 sq . ft ., 2-1/2” spacing .
Family Room/Zone 2 = 1 spool, 240 sq . ft ., 3” spacing
190 ft . of strap, or eight 25-ft . rolls .

Kitchen and SunRoom (normal and high heat loss, framed floor construction)
One zone, 240 volts: Kitchen = 1 spool; 120 sq . ft .; 3” spacing .

Sunroom = 1 spool; 112 sq . ft .; 2” spacing .
104 ft . of strap, or five 25-ft . rolls .

Advertising