Detail of shower curb – Infloor Standard Electric Cable User Manual

Page 23

Advertising
background image

Infloor Installation Manual

23

Detail of Shower Curb

Infloor Cable

Factory Splice

Shower Curb

Tile

Thinset Mortar

Notches in Shower Curb

(to avoid sharp bends in cable)

Master Bathroom (normal heat loss, framed floor construction)

Two zones, 120 volts: Bathroom/Zone 1a = 1 spool; 60 sq. ft., 3” spacing.

Bathroom (shower) /Zone 1b = 1 spool; 20 sq. ft., 3” spacing.

Vanity

Bath Tub

Shower

Toilet

Control

Strap

Spool

Termination

Shower

Curb

Floor

Sensor

Zone 1a

Zone 1b

IMPORTANT: Example of Type (-W) Cable (see UL Label on product), where

cable is installed in a shower area and enters over the curb. See Step 5.20

for complete details and Cautions. This application into a shower area must

be verified by the local inspector or the authority having jurisdiction.

Install cables

at least 6” away

from toilet rings