0 (0x00) = disable AUTO report function.
(by time interval)
AUTO report timer:
1 (0x01) = 0.5 hr
2 (0x02) = 1.0 hr,

(default)

3 (0x03) = 1.5 hrs
4 (0x04) = 2.0 hrs
5 (0x05) = 2.5 hrs
6 (0x06) = 3.0 hrs
7 (0x07) = 3.5 hrs
8 (0x08) = 4.0 hrs
9 (0x09) = 4.5 hrs
10 (0x0A) = 5.0 hrs
11 (0x0B) = 5.5 hrs
12 (0x0C) = 6.0 hrs
13 (0x0D) = 6.5 hrs
14 (0x0E) = 7.0 hrs
15 (0x0F) = 7.5 hrs
16 (0x10) = 8.0 hrs

12 (0x0C)

AUTO report by time
interval.
(It will report room
temperature only)

*User can use this
function to enhance
batteries service life.

Parameter value range

Parameter No.

Functions

Temperature offset value.
Formula: Display temperature
= sensor reading value + offset value
(unit = degree F)

o

0 (0x00) = 0 F

(default)

o o

1 (0x01) = 1 F (0.5 C)

o o

2 (0x02) = 2 F (1.0 C)

o o

3 (0x03) = 3 F (1.5 C)

o o

4 (0x04) = 4 F (2.0 C)

o o

5 (0x05) = 5 F (2.5 C)

o o

6 (0x06) = 6 F (3.0 C)

o o

7 (0x07) = 7 F (3.5 C)

o o

8 (0x08) = 8 F (4.0 C)

o o

9 (0x09) = 9 F (4.5 C)

o o

10 (0x0A) = 10 F (5.0 C)

o o

-1 (0xFF) = -1 F (-0.5 C)

o o

-2 (0xFE) = -2 F (-1.0 C)

o o

-3 (0xFD) = -3 F (-1.5 C)

o o

-4 (0xFC) = -4 F (-2.0 C)

o o

-5 (0xFB) = -5 F (-2.5 C)

o o

-6 (0xFA) = -6 F (-3.0 C)

o o

-7 (0xF9) = -7 F (-3.5 C)

o o

-8 (0xF8) = -8 F (-4.0 C)

o o

-9 (0xF7) = -9 F (-4.5 C)

o o

-10 (0xF6) = -10 F (-5.0 C)

13 (0x0D)

Sensor temperature
calibration.
(This parameter is
used to change the
display temperature
to match with your
previous thermostat,
or to match another
thermostat already in
your home)