Figure 5. Heat pump HVAC system wiring

Figure 6. Non-heat pump 2-wires system wiring

Figure 7.Heat pump 2-wires system wiring

Thermostat should be powered by batteries and support heating control only.

Thermostat should be powered by batteries and support heating control only.
For heat pump output, there is a 3 minutes off time for heat pump protection.

8

Heat Pump HVAC System

O - Cool changeover (heat pump)

B - Heat changeover (heat pump)

nd

W2 - 2 stage heater

G - Fan

Y - Compressor

R - 24Vac Power

C - 24Vac Common

O
B

W2
W1

G

Y

RC
RH

C

Brown

Green
Yellow

Red
Black

Blue

Orange

ELECTH

HPUMP

J2

ELECTH

HPUMP

J2

Y - Compressor

R - 24Vac Power

O
B

W2
W1

G

Y

RC
RH

C

Yellow

Red

HG

HE

J1

HG

HE

J1

ELECTH

HPUMP

J2

st

W1 - 1 stage heater

R - 24Vac Power

O
B

W2
W1

G

Y

RC
RH

C

White

Red

Advertising