108

RC2500 Antenna Controller

Appendix I

Replacing the SA 8840 Controller

Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas • 66218-9680 • USA

www.researchconcepts.com

Antenna I/O Connector

J7, located to the right of J4, is a DB-25 plug that acts as the Antenna I/O connector.

The port consists of six solid-state low-side relay drivers rated at 700mA sink each. The maximum

allowable voltage is +27VDC on these drivers. The individual pin definitions are shown in the table

below.

Pin #

Description

1

Azimuth CW limit input, 24VDC low current, (0.4V = CW Limit reached)

2

Polarization CW limit input, 24VDC low current, (0.4V = CW Limit reached)

3

Elevation Down limit input, 24VDC low current, (0.4V = Down Limit reached)

4

Pedestal_Override input, 24VDC low current, (+24V=RC2500 is disabled)

5

Azimuth Drive Fault input, 24VDC low current, not used (to be jumpered to +24VDC)

6

not used

7

not used

8

not used

9

not used

10

+24VDC to be jumpered to AZ Drive Fault line J7 pin 5

11

Polarization Enable output, open collector, 700mA sink. (0.4V = POL move)

12

Elevation Direction output, open collector, 700mA sink. (0.4V = Direction UP)

13

Elevation Enable output, open collector, 700mA sink. (0.4V = EL move)

14

Polarization CCW limit input, 24VDC low current, (04V= CCW limit reached)

15

Elevation Up limit input, 24VDC low current, (0.4V=UP limit reached)

16

Azimuth CCW limit, 24VDC low current, (0.4V=CCW limit reached)

17

not used

18

Elevation Drive Fault input, 24VDC low current, not used (to be jumpered to +24VDC)

19

Intercom, not used

20

Power Supply Common, (Referenced to the A.I.U. Loop Supply)

21

Azimuth Enable output, open collector, 700mA sink. (0.4V = AZ move)

22

Spare, not used

23

+24VDC to be jumpered to EL Fault line, J7 pin 18

24

Polarization Direction output, open collector 700mA sink. (0.4V = POL CW)

26

Azimuth Direction output, open collector, 700mA sink. (0.4V = AZ CW)

In addition to providing power to A.I.U. circuitry, the Voltage on pin 23 is used to power the electronic

components that reside on the A.I.U.-side of the opto-isolation barrier. When no power is present at

Intest (which is passed to Intest return when the controller is in a non-error condition), this pin must still

be powered by between +15 and +28V (and its return line connected to “-“) in order for the RC2500 drive

system to function.

Advertising