Antenna I/O Connector

J7, located to the right of J4, is a DB-25 plug identified as the Antenna I/O connector. This connector

acts as the antenna motion control port of the RC2500. The port consists of 6 solid-state high-side

Darlington drivers rated at 20mA source each.

RC2500 Pin #
& (resource #)

Description

SSE Signal Name

1 (PA1)

Azimuth Drive CW, pull-up drive, 20mA max source. (5
V = move CW).

AZ Right

2

Drive Common (return path for AZ, EL, & POL drive
command lines) )

Relay Return

3 (PA0)

Azimuth Drive CCW, pull-up drive, 20mA max source.
(5 V = move CCW)

AZ Left

4 (PA4)

Elevation Drive Up, pull-up drive, 20mA max source. (5
V = move Up

EL Up

5

Drive Common (return path for AZ, EL, & POL drive
command lines) )

Relay Return

6 (PA3)

Elevation Drive Down, pull-up drive, 20mA max source.
(5 V = move Down

EL Down

7 (PA7)

Polarization Drive CW, pull-up drive, 20mA max source.
(5 V = move CW)

No connect T.B.D.

8

Drive Common (return path for AZ, EL, & POL drive
command lines) )

Relay Return

9 (PA6)

Polarization Drive CCW, pull-up drive, 20mA max source.
(5 V = move CW)

No connect T.B.D.

10 (PB0)

reserved input (same as J6 pin16)

No connect

11 nc

unused pin

No connect

12 nc

unused pin

No connect

13 nc

unused pin

No connect

14 (P2.4)

unused input

No connect

15 (HSI.1)

unused input

No connect

16 (PB7)

unused input

No connect

17 (PB0,
HSI.1,P2.4)

unused input return; (same as J6-4)

No connect

18 (PB0
HSI.1,P2.4)

unused input return; (same as J6-4)

No connect

19 (PB7)

unused input

No connect

20

unused pin

No connect

21 (PA2)

unused output

No connect

22 (PA5)

unused output

No connect

23 (PC2)

unused output

No connect

24 (PB6)

Local/Remote Status input, 12 VDC low current, (12V =
AIU in remote mode…RC2500 active)

+12V supply from AIU

25 (PB6)

Local/Remote Status input return

Relay Return