Resolver Input Connector, J2

This appendix section replaces Section 3.3.1.3 of the Manual.

J2, located on the left side of the back panel is the Resolver Input connector. This port, based on a DB-

50P connector, supports three resolver inputs. The table below indicates the pin # and their usage.

J2 Pin #
& (resource #)

Description

APC100/300 Pin #

1

AZ SIN HI

1 AZ SIN HI

2-4

not used

2-4 not used

5

GROUND FOR DRAIN WIRE

5 not used

6-7

not used

6-7 not used

8

EL COS -

8 EL COS RTN

9-11

not used

9-11 not used

12

POL SIN -

12 POL SIN RTN

13

POL COS +

13 POL COS HI

14-15

No Connection

14-15 not used

16

EL REF -

16 EL REF RTN

17

POL REF +

17 POL REF HI

18

No Connection

18 not used

19

AZ COS -

19 AZ COS RTN

20-22

No Connection

20-22 not used

23

EL SIN -

23 EL SIN RTN

24

EL COS +

24 EL COS HI

25-27

No Connection

25-27 not used

28

POL SIN +

28 POL SIN HI

29-30

No Connection

29-30 not used

31

AZ REF -

31 AZ REF RTN

32

EL REF +

32 EL REF HI

33

No Connection

33 not used

34

AZ SIN -

34 AZ SIN RTN

35

AZ COS +

35 AZ COS HI

36-38

No Connection

36-38 not used

39

EL SIN +

39 EL SIN HI

40-45

No Connection

40-45 not used

46

POL COS -

46 POL COS RTN

47

AZ REF +

47 AZ REF HI

48-49

No Connection

48-49 not used

50

POL REF -

50 POL REF RTN