Appendix d – the rci rs422 interface specificatio, Introduction, Electrical specifications – Research Concepts RC2500 User Manual

Page 78: Physical specifications, Appendix d – the rci rs422 interface specification

Advertising
background image

RC2500 Antenna Controller

Appendix D

RCI RS-422 Specification

71

Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas 66218-9680 • USA

www.researchconcepts.com

Appendix D – The RCI RS422 Interface Specification

Introduction

The purpose of this document is to explain the key parameters needed by a user to interface to the RCI

RS422 Interface. This interface is compatible with the SAbus and can be readily integrated into an

existing SAbus network. A few query and control commands are all that are needed to control the

equipment and fetch all data from it. The user should refer to RCI document ‘RC2500 Communications

Protocol’ for the specific program commands and descriptions of their functions.

Electrical Specifications

RS-422 is a unipolar, balanced, 5-volt serial interface designed to connect equipment which must

exchange data over considerable distances with high-noise immunity and high speed. Standard IC

drivers and receivers are available for RS-422 that convert to and from TTL logic levels. The RS-422

drivers/receivers in the controllers allow up to 32 devices to be connected in parallel with up to 1,500 feet

between the master and group of controllers.

Physical Specifications

The physical implementation of the interface takes the form of a 9-pin "D" connector located on the rear

panel of the controller. This connector and its wiring is compatible with EIA RS-449, which is the

mechanical specification for RS-422/423-compatible equipment. The 9-pin connector chosen is

described as the secondary interface in RS-449 and has only the four data lines and shield. No hardware

handshaking is used in the protocol, so all the control lines specified for the standard 37-pin connector

are not needed. The controller operates as a slave only and has a female connector, whereas master

devices have male connectors. Multiple controllers, connected in a daisy chain fashion, can operate in

electrical parallel with only a single 5-conductor cable required to connect all devices controlled by a

master. Figure 1 illustrates the connection of a master and multiple controllers.

RS-422 Protocol

The interface is a multi-drop, balanced line, asynchronous, full-duplex communications link designed to

interconnect equipment for remote control and switching applications. Products that are compatible can

be linked together over a parallel-connected 4-wire circuit without regard to their particular function.