Controller functions – Scotsman HID312 Service Manual User Manual

Page 15

Advertising
background image

HID312, HID525, HID540

Service Manual

April 2015

Page 15

Controller Functions

The controller has features for the service technician. Some details

• Any auger motor failure is an immediate shut down. Because of the critical nature of that failure there is no

auto restart from an auger error.

• An open Water Sensor (dry probes) will stop the machine. Because water can be restored at any time,

whenever both Water Sensor probes are wet again AND the compressor has been off for at least two minutes,

ice making will restart.

• An open High Pressure switch will stop the machine. Because the pressure switch is an automatic reset,

when it closes AND the compressor has been off for at least two minutes, ice making will restart.

• Fault Code View: Push and HOLD the

vend disable button then push and hold the on/off button for 3

seconds or until Status light is on. Release both. Pushing Clean will cycle thru the available codes, the total

number of codes stored is 30.

• Clear codes: Push and HOLD the

vend disable button then push and hold the Clean button for about 3

seconds. The display code will blink 3 times. Release both.

• The compressor will not restart until it has been off for at least 2 minutes.
• There is a Test Mode. The Test Mode operates each load in sequence to confirm that it is being powered

by the controller.
To start Test Mode: Push and HOLD the ON/OFF button; at the same time, push and HOLD the CLEAN button.

When a “d” appears in the code display, release the buttons, the test mode will begin.

Time (seconds)

On

Off

0

Compressor

Auger Gear Motor, Water Disp, Ice Disp

10

Compressor and Auger Gear Motor

Water Disp, Ice Disp

20

Auger Gear Motor

Compressor, Water Disp, Ice Disp

30

Water Dispense

Auger Gear Motor, Compressor, Ice Disp

35

Ice Dispense

Auger Gear Motor, Compressor, Water Disp

40

None

All – Test Complete

• The Time to Clean indicator light glows when 6 months of power up time have elapsed. When it is on it

does NOT stop ice making. It is cleared and reset when the Cleaning process has been completed.

• The Cleaning process, described in detail in the Maintenance section, is initiated by a press of the Clean

button. The auger motor will be operating during the entire Clean mode. No ice will be made. The scale is

dissolved by the action of the scale remover and the auger’s motion.

• Pushing the Disable switch closes contacts of the switch, signalling the controller to ignore the dispense

sensor’s signals for 60 seconds.

• USB firmware updates may become available. To update the unit must be in Test Mode and then a USB

stick with ONLY the update on it is inserted into the USB connector. L will be displayed during the Loading

process. After a few seconds the top five LEDs begin scrolling up for about 75 seconds then the LEDs start

scrolling down for about 20 seconds. At the end “0” is displayed. Unplug the USB drive.
Note: If during the update process the display flashes between “L” and “F” that means that the Load Failed. If

that happens, unplug the USB drive, then power cycle the control board. If “0” is not displayed, press the On/

Off button. The controller will revert to the original firmware.

Advertising