Placement – Scotsman HID312 Service Manual User Manual

Page 7

Advertising
background image

HID312, HID525, HID540

Service Manual

April 2015

Page 7

Placement

The location of the equipment should be selected

with care. Consideration should be given to allow

adequate space on the sides for air cooled models to

breathe.
Minimum clearances for air cooled models:

• 6 inches or 15 cm at each side
• 2 inches or 5 cm above, 10” or 25 cm more to

allow auger removal when ceiling is fixed.

• 6 inches or 15 cm at the back.

Air cooled models flow air left to right. More space

than the minimum at the sides will maximize

performance.

The power outlet should be located within the length

of the supplied power cord. If placed on a counter,

the counter must be strong enough to support the

weight of the unit. Space above the cabinet should be

allowed for service and maintenance. If legs will be

used, allow space for the total cabinet height.
Air cooled models in a small room will require

ventilation to exhaust the heat they produce. They

also produce some added noise from the fan.

Noise sensitive areas should consider water cooled

equipment or the machine located where the noise

from ice making is not objectionable.
Nearby infrared emitters or a window that allows

sunlight to shine on a dispensing sensor may cause

the unit to dispense ice or water without a container to

trigger it.

Cafeteria applications.
The unit can be placed in a cafeteria line for ice and

water. As some users sometimes dispense too much

ice, high volume use may require the drip tray to be

occasionally cleared of spilled ice.

Airflow Direction

Advertising