Specifications

The ice maker-dispenser is designed to be installed

indoors, in a controlled environment. Although

it can operate in a wide range of air and water

temperatures, it will provide the best performance if

not subject to extremes.
Air Temperature Limitations

• Maximum: 100

o

F. or 38

o

C.

• Minimum: 50

o

F. or 10

o

C.

Water Temperature Limitations

• Maximum: 100

o

F. or 38

o

C.

• Minimum: 40

o

F. or 4.4

o

C.

Water Pressure, potable

• Maximum: 80 PSI or 5.5 Bar
• Minimum: 20 PSI or 1.3 Bar

Water Pressure, condenser inlet

• Maximum: 145 PSI or 10 Bar
• Minimum: 20 PSI or 1.3 bar; can be as low as 5

PSI or .3 Bar if clean & supplied with 45

o

F. water)

Condenser GPM

• 70

o

F. water: .25 or .95 LPM

• 50

o

F. water: .15 or .57 LPM

Water Conductivity:

• Minimum: 10 microSiemens/cm

RO water may be supplied to the potable water

system, but if it has less than the above conductivity,

the water level sensor will not detect water and the

unit will not make ice.
Deionized water will not work and isn’t recommended.
Voltage - 60 Hz

• Maximum: 126 Minimum: 104

Operating the machine outside of any of the above

limitations is considered abuse and any resulting

damage is not covered by warranty and could cause a

complete loss of warranty coverage.

Warranty Information
The warranty statement for this product is provided

separately from this manual. Refer to it for applicable

coverage. In general warranty covers defects

in material or workmanship. It does not cover

maintenance, corrections to installations, or situations

when the machine is operated in circumstances that

exceed the limitations printed above.
Product Information
The product is an ice maker-dispenser. It is designed

to be installed on a countertop or on a specific

machine stand.

• All models require a drain. An internal drain basin

separates the ice storage bin’s drain from the drip tray

drain.

• A backflow preventer may be required by local

plumbing codes.

• 60 Hz model has a 7.5 ft. power cord with NEMA

5-15P plug.

• Air cooled models flow air left to right and include

a cleanable air filter.

• 4” or 10 cm legs are optional for counter models.

Thread size 3/8 - 16.

• Special models are required for wall mounting.
• Ice or water vending is triggered by touch free

sensors, no other activation method is available.

• For available options and kits, see sales literature.

Scotsman Ice Systems are designed and

manufactured with the highest regard for safety and

performance.
Scotsman assumes no liability or responsibility of

any kind for products manufactured by Scotsman

that have been altered in any way, including the use

of any part and/or other components not specifically

approved by Scotsman.
Scotsman reserves the right to make design changes

and/or improvements at any time. Specifications and

design are subject to change without notice.