Troubleshooting – Scotsman HID312 Service Manual User Manual

Page 25

Advertising
background image

HID312, HID525, HID540

Service Manual

April 2015

Page 25

Troubleshooting

Symptom

Possible Cause

Probable Correction

No ice in bin

Auger motor not operating

Open windings. Check motor windings and replace

if open.
Gear reducer seized, replace gear reducer.
Auger bearings seized, replace bearings and seal
No power to auger motor, Auger light is ON.

Replace controller.
Code 2 in controller. Check that sensor rotates with

motor and isn’t loose. Tighten screw if loose.
Code 1 in controller, replace auger motor.

Compressor not operating

Contactor coil is open, check and replace if needed.
Compressor hot and overheated, check start relay

and start capacitor
No power to compressor or contactor coil.

Compressor light is ON. Replace controller.
Compressor at room temperature, will not start.

Check windings. If open, replace compressor. If not

open, check/replace start relay and start capacitor.

Compressor operating,

auger turning, no ice is

made

Check refrigeration system, TXV may be set to too

much superheat or the system is low on refrigerant.

Excessive noise

Tubing contact

Check for tubes rattling and panels not tight

Fan blade out of balance

Replace fan blade

Compressor noisy

Replace compressor

Moaning noise when

making ice

Water seal being

compressed

Gear reducer bearing failure, replace gear reducer

Dispense motor not

turning

No voltage to it

Check dispense light, if on there should be voltage.

If none, replace motor.

Wrong voltage motor

Check motor label, install correct motor.

Dispense motor working,

but ice in bin not moving

Broken ice agitator

Replace and check for mechanical cause for

breakage

Broken drive pin

Replace and check for worn hole in dispense motor

shaft

Too much ice in drip tray Users are taking ice and

dumping it

Glass size too small, use larger glass.

Water leak near front

Drip tray not in position,

hard to push all the way in

Add small amount of food grade lube to the drip tray

drain stub or o-ring in drain fitting.

Glass does not trigger

dispense light

Glass is too clear

Confirm by testing dispense with hand behind glass.