IMPORTANT:

Vent-free fireplaces add moisture

to the air. Although this is beneficial, installing fire-

place in rooms without enough ventilation air may

cause mildew to form from too much moisture. See

Air for Combustion and Ventilation, page 7.
Note:

Your fireplace is designed to be used in zero

clearance installations. Wall or framing material can be

placed directly against any exterior surface on the rear,

sides or top of your fireplace, except where standoff

spacers are integrally attached. If standoff spacers are

attached to your fireplace, these spacers can be placed

directly against wall or framing materials.
Note:

When installing fireplace directly on carpet-

ing, tile or other combustible material, other than

wood flooring, the fireplace shall be installed on a

metal or wood panel extending the full width and

depth of the fireplace.
Use the dimensions shown for rough openings to

create the easiest installation (see Built-In Fire-

place Installation, page 11).

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP)

for your unit. If your gas supply is not correct, do

not install fireplace. Call dealer where you bought

fireplace for proper type fireplace.

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

INSTALLATION ITEMS

Before installing fireplace, make sure you have

the items listed below.
• external regulator (supplied by installer, for

propane/LP units only)

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection*
• ground joint union
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 40.

INSTALLATION

Continued

FIREPLACE CLEARANCES

WARNING: Maintain the

minimum clearances shown in

Figure 6, page 11. If you can,

provide greater clearances from

floor, ceiling and joining wall.

NOTICE: If you install the fire-

place in a bedroom, some

building codes require that the

fireplace/mantel system be se-

cured to (or within) a wall. You

can position fireplace in an op-

tional cabinet or corner mantel.

You can also recess fireplace

into the wall.

If your fireplace is to be used with an optional

mantel, the installation instructions included with

your mantel shows an CSA approved method of

attaching the fireplace/mantel system to a wall.

IMPORTANT:

Only use optional cabinet or

corner mantels specified in this manual. Purchase

the optional mantel from your dealer (see Acces-

sories, page 40).
If your fireplace is to be recessed into the wall,

see Built-In Fireplace Installation on page 11 to

secure your fireplace into the wall.

CAUTION: If you install the

fireplace in a home garage

• fireplace pilot and burner must

be at least 18" above floor.

• locate fireplace where moving

vehicle will not hit it.

For convenience and efficiency, install fireplace
• where there is easy access for operation, inspec-

tion and service

• in coldest part of room
An optional blower kit is available from your

dealer. See Accessories, page 40. If planning to use

blower, follow instructions provided with blower

for power source.