CONNECTING FIREPLACE TO GAS
SUPPLY

Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not pro-

vided)

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas

line is provided to allow acces-

sibility from the fireplace (see

Figure 1, page 5). The flexible

gas supply line connection to the

equipment shutoff valve should

be accessible.

1. Route flexible gas line, included, from fire-

place control to equipment shutoff valve

through side or rear access holes in outer

casing (see Figure 1, page 5).

2. Apply pipe joint sealant lightly to male threads

of gas connector attached to flexible gas line/

equipment shutoff valve (see Figure 23).

CAUTION: Avoid damage to

regulator. Hold gas regulator

with wrench when connecting

it to gas piping and/or fittings

(Thermostat-Controlled Models

Only).

CAUTION: Avoid damage to

gas control. Hold gas control

with wrench when connecting

it to gas piping and/or fittings

(Remote-Ready Models Only).

3. Check all gas connections for leaks. See

Checking Gas Connections.

4. Feed flexible gas line into fireplace base area

while replacing branch support. Make sure the

entire flexible gas line is in fireplace base area.

INSTALLATION

Continued

Figure 23 - Attaching Flexible Gas Line

to Equipment Shutoff Valve

Flexible Gas Line
from Fireplace Gas
Regulator Provided
With Fireplace

To Gas Regulator
(Thermostat-Controlled
Models) or Control Valve
(Remote-Ready Models)

Equipment
Shutoff Valve

PROPANE/LP
To External
Regulator

NATURAL
To Gas Supply

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections, internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an open

flame to check for a leak. Apply

a noncorrosive leak detection

fluid to all joints. Bubbles form-

ing show a leak. Correct all leaks

at once.

CAUTION: Make sure exter-

nal regulator has been installed

between propane/LP supply

and fireplace. See guidelines

under

Connecting to Gas Sup-

ply, page 17.

PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect appliance with its appliance main gas

valve (control valve) and equipment shutoff valve

from gas supply piping system. Pressures in excess

of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where equipment

shutoff valve was connected.

Advertising