INSTALLATION

Continued

OPTIONAL WALL MOUNTED
THERMOSTAT - GWMT1
(Remote-Ready Models Only)

WARNING: Read and fol-

low installation instructions.

Installation should be done by

a qualified installer familiar with

low-voltage wiring procedures.

WARNING: Do not connect

this thermostat to any electrical

source! Electrical shock and/or

fire hazard will occur.

1. Disconnect jumper wire from control valve

(see Figure 31).

2. Connect one terminal of 25 ft. wire to “TPTH”

terminal on control valve (see Figure 31).

3. Connect remaining wire terminal to the “TH”

terminal on the control valve. Make sure that

wire terminals are in the positions on your unit

as pictured in Figure 31.

4. Route the 25 ft. wire to a convenient location

to mount your thermostat (no outside wall).

IMPORTANT:

The wire may be shortened but

must not be lengthened.

The thermostat should be mounted 54" above

the floor in a location where there is good

air circulation. Avoid heat sources such as

lamps, direct sunlight, fireplace or heat and

air conditioning ducts.

5. Gently remove the cover of the thermostat

from the base. Grasp the sides of the cover

firmly and pull to separate from the base.

6. Feed the electrical wires through the rectangular

slots on each side of the base (see Figure 32).

WARNING: Do not con-

nect the thermostat to a power

source. Electrical shock and/or

a fire hazard will occur.

7. Connect one bare wire end to each terminal

(“W” and “R”) of the thermostat base (see

Figure 33).

8. Install the base onto the wall with the provided

screws.

Figure 31 - Connecting Wire Terminals

One terminal
of 25 ft. wire

Control
Valve

Jumper Wire

9. Move the temperature adjustment back and forth

to insure the bimetal is free from restrictions.

10. Replace the cover onto the base. (Upon in-

stallation, the thermostat must be allowed to

stabilize at room temperature for a minimum

of 30 minutes for proper operation).

11. Set switch on fireplace to Auto position.
12. Set the temperature adjustment to the desired

setting. This thermostat has been electroni-

cally calibrated at the factory. No adjustment

or leveling is necessary.

Figure 32 - Back View of Thermostat

Base

Feed wires through rectangular slots

W

R

Figure 33 - Thermostat Base Terminals

“W” and “R”

Terminal “W”

Terminal “R”