Local codes, Safety information – Desa VMH10TPC User Manual

Page 4

Advertising
background image

www.desatech.com

112462-01F

4

SAFETY INFORMATION

Continued

1. This appliance is only for use with the type of

gas indicated on the rating plate. This appliance

is not convertible for use with other gases.

2. Do not place propane/LP supply tank(s) in-

side any structure. Locate propane/LP supply

tank(s) outdoors.

3. If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use

any phone in your building

• immediately call your gas supplier from a

neighborʼs phone. Follow the gas supplierʼs

instructions

• if you cannot reach your gas supplier, call

the fire department

4. This fireplace shall not be installed in a bath-

room.

5. Do not use this fireplace as a wood-burning

fireplace. Use only the logs provided with the

fireplace.

6. Do not add extra logs or ornaments such as

pine cones, vermiculite or rock wool. Using

these added items can cause sooting. Do not

add lava rock around base. Rock and debris

could fall into the control area of fireplace.

7. This fireplace is designed to be smokeless.

If logs ever appear to smoke, turn off fire-

place and call a qualified service person.

Note:

During initial operation, slight smoking

could occur due to log curing and fireplace

burning manufacturing residues.

8. To prevent the creation of soot, follow the instruc-

tions in Cleaning and Maintenance, page 30.

9. Before using furniture polish, wax, carpet

cleaner or similar products, turn fireplace off.

If heated, the vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

10. This fireplace needs fresh air ventilation to run

properly. This fireplace has an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS shuts down the fireplace if not enough

fresh air is available. See Air for Combustion

and Ventilation, page 7. If fireplace keeps

shutting off, see Troubleshooting, page 31.

11. Keep all air openings in front and at bottom

of heater clear and free of debris. This will

insure enough air for proper combustion.

12. Do not run fireplace

• where flammable liquids or vapors are used

or stored.

• under dusty conditions.

13. Do not use this fireplace to cook food or burn

paper or other objects.

14. Never place any objects in the fireplace or

on logs.

15. Do not use fireplace if any part has been under

water. Immediately call a qualified service

technician to inspect the room fireplace and to

replace any part of the control system and any

gas control which has been under water.

16. Turn off and unplug fireplace and let cool

before servicing. Only a qualified service

person should service and repair fireplace.

17. Operating fireplace above elevations of 4,500

feet could cause pilot outage.

18. Do not operate fireplace if any log is broken.

Do not operate fireplace if a log is chipped

(dime-sized or larger).

19. To prevent performance problems, do not use

propane/LP fuel tank of less than 100 lbs.

capacity.

20. Provide adequate clearances around air

openings.

LOCAL CODES

Install and use fireplace with care. Follow all local

codes. In the absence of local codes, use the lat-

est edition of The National Fuel Gas Code ANSI

Z223.1/NFPA 54*.
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269