Minimum Clearances For Side Combustible
Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 6.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 6).

B. Clearances from the top of the fireplace

opening to the ceiling should not be less

than 36".

C. For mantel clearances, see Figure 10 on

page 13.

Figure 6 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

*

Example

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Right Sides

Bottom and

Rear

36

"

6"

0"

INSTALLATION

Continued

Actual Framing

Height

26"

26

7

/

8

"

Front Width 26

3

/

4

"

26

7

/

8

"

Depth

9

1

/

2

"

10

1

/

2

"

Bottom

3/4"

3/4"

1. Frame in rough opening. Use dimensions shown

in Figure 7 for the rough opening. If installing in

a corner, use dimensions shown in Figure 8 for

the rough opening. The height is 26

7

/

8

" which

is the same as the wall opening above.

2. If installing GA3450TA blower accessory, do

so at this time. Follow instructions included

with blower accessory.

Note:

If not installing blower accessory, you

may wish to run electrical wiring to your

fireplace for future blower installation (see

Accessories, page 40). Use only approved

three-wire electrical wiring.

WARNING: If pre-wiring, do

not connect wiring to any electri-

cal source at this time.
Install fireplace electrical outlet

and connect wiring to outlet

before connecting to electrical

source. The fireplace electri-

cal outlet is included with the

GA3450TA blower accessory.
Only use the fireplace electri-

cal outlet supplied with the

GA3450TA blower accessory.

Note:

A qualified installer should make all electri-

cal connections.

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves install-

ing fireplace into a framed-in enclosure. This makes

the front of fireplace flush with wall. An optional

trim kit accessory is available (see Accessories,

page 40). Trim will extend past sides of fireplace

approximately 1/2". This will cover the rough edges

of the wall opening. If installing a built-in mantel

above the fireplace, you must follow the clearances

shown in Figure 10, page 13. Follow the instruc-

tions below to install the fireplace in this manner.

26

7

/

8

"

26

7

/

8

"

3/4" Off
The Floor
Minimum

10

1

/

2

"

Figure 8 - Rough Opening for Installing

in Corner

Figure 7 - Rough Opening for Installing

in Wall

36

5

/

8

"

25

7

/

8

"

51

3

/

4

"

26

7

/

8

"