3
2
1

Figure 16 - Installing Blower (Thermostat Unit Shown)

Wire Harness

Blower Bracket Assembly

Screw

Wire
Harness

Switch

Baffle

Wiring Routing Hole
in Baffle

Switch
Plate

Blue

Red

Rear Fan
Switch Cover

Snap
Bushing

Power Cord

Black

Blower Mounting
Holes

Lower Louver Door

Front Fan
Switch
Cover

INSTALLATION

Continued

6. In top of the fireplace cabinet, locate the

four mounting holes on the outer casing.

Align these four holes with those on the

blower bracket assembly. Attach blower

bracket assembly to the outer casing with

4 #10 screws provided (see Figure 16).

7. Route the wire harness through the hole

in left side of baffle. Pull wire harness

through lower opening of firebox (see

Figure 16).

8. Insert the 4 wire harnesses into one of the

round holes in the rear of the fan switch cover

and through the rectangular hole on front of

the fan switch cover (see Figure 16).

9. Reconnect red wire to switch position 3.

Reconnect blue wire to switch position 1.

Reconnect green and white wires.

10. Install the switch plate on front of fan

switch cover with 2 #10 screws provided

(see Figure 18, page 16). Using screw

removed in step one, reconnect front and

rear of fan switch cover.

Figure 17 - Wiring Diagram For Blower

Accessory Standard Installation

Red

Red

Fan Switch

(Auto/Off/On)

Blue

Blue

Thermostat

Switch

(N.O.)

Green

White

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

3

Auto

Advertising